Operation (continued)
Care and Cleaning
To clean, wipe down with a damp cloth and towel dry.
Troubleshooting
Problem Possible Cause Solution
There are leaks from the
handle.
The bonnet nut has come loose and/or the
washer is dirty or damaged.
Tighten the bonnet nut.
Clean or replace the washer.
The aerator has an
irregular or reduced
water ow.
Remove the aerator and
check for debris.
Ensure that the rubber washer
is properly installed.
The water will not shut off
completely.
The cartridge is dirty or broken. Remove the handle to check
the cartridge.
Clean or replace.
The aerator is dirty or mis-tted.
Do not use abrasive cleaners, steel wool, or harsh chemicals when cleaning this faucet, or the warranty will
be voided.
NOTE: Refer to the service parts section in this manual for
a detailed drawing showing the location of the parts listed
below.
2
Removing the quick connector
If it is necessary to remove the quick connector
(1), squeeze the tabs (2) on the quick connector
and then pull down to disconnect.
Squeeze
2
Pull
down
1